流量:15.7L/H,壓力:7Bar,美國(guó)帕斯菲達(dá)pulsafeeder機(jī)械隔膜計(jì)量泵X2-100加藥泵
200、250系列機(jī)械隔膜計(jì)量泵流量:15.7L/H,壓力:7Bar,美國(guó)帕斯菲達(dá)pulsafeeder機(jī)械隔膜計(jì)量泵X2-100加藥泵的詳細(xì)介紹
*為特殊使用場(chǎng)所而設(shè)計(jì)之高壓計(jì)量泵 *高效率風(fēng)冷式馬達(dá),油浸式齒輪箱 *金屬增強(qiáng)隔膜,短距離動(dòng)作沖程,壽命長(zhǎng) *計(jì)量**,輸出量可隨意調(diào)整 *高扭力齒輪組,確保高壓力時(shí)順利啟動(dòng)運(yùn)轉(zhuǎn)
流量:15.7L/H,壓力:7Bar,美國(guó)帕斯菲達(dá)pulsafeeder機(jī)械隔膜計(jì)量泵X2-100加藥泵
1. Install the pump in a place convenient for its future maintenance and inspection, then fix it to prevent vibration.
2. Protective caps must be removed prior to installing tubing onto valve assemblies. Use tubing of specified size. Connect the tubing to the suction side securely to prevent the entranee of outside air. Make sure that there is no liquid leakage on the discharge side.
3. Each pump is equipped with a three-prong plug. Always be sure the pump is grounded. To disconnect, do not pull wire, but grip the plug with fingers and pull out.
4. Chemicals used may be dangerous and should be used carefully and according to warnings on the label. Follow the di recti ons give n with each type of chemical. Do not assume chemicals are the same because they look alike. Always store chemicals in a safe location away from children and others. We cannot be responsible for the misuse of chemicals being fed by the pump. Always have the material safety data sheet (MSDS) available for any fluid being pumped.
5. Arrows on the pump head and injection fitting indicate chemical flow. When properly installed, these arrows should be pointing upward.
6. When metering hazardous material NO NOT use plastic tubing. Strictly use proper rigid pipe. Consult supplier for special adaptors or valve assemblies.
7. Standard white discharge tubing is not recommended for installations exposed to direct sunlight. Consult supplier for special black tubing.
8. When using pump with pressurized systems, make sure the pressure of the system does not exceeatne maximum pressure rating on the pump data label. Be sure to de-pressurize system prior to hookup or disconnecting the metering pumps.
9. If the discharge point is below the liquid level of the source or it the discharge pressure is less than the suction pressure, siphoning may occur. To correct this condition, install an anti-siphon valve or other anti-siphon device. Check local regulations which may apply. (Ref. Figure H).